[protected]
Metrology & Production Control

Metrology and production control

Optical and mechanical verification that carries a part from first article to repeat production release.

WAVEFRONT
632.8 nm, RMS
DRAWINGS
ISO 10110
RELEASE
FAI → lots
REPORTS
Per lot

Inspection methods

Optical acceptance is interferometric: the transmitted wavefront of the finished lens is measured at 632.8 nm and reported as RMS against the drawing. Surface form is checked by profilometry against the released profile, and diameter, thickness, centring and surface imperfections are inspected to the ISO 10110 callouts on the drawing.

Where the in-house laboratory is covered by a valid CNAS accreditation, testing and calibration activities are performed within the approved accreditation scope.

The first article freezes the drawing revision and the acceptance criteria. Repeat lots are released against that record, with lot documentation and, on request, measured reports. The callouts are explained in reading ISO 10110 callouts and the release path in first article and lot release.

Interferometric test of a lens in transmission: fringes give the RMS transmitted wavefront.
Interferometric test of a lens in transmission: fringes give the RMS transmitted wavefront.
In-house operations
Interferometry
Transmitted wavefront of finished lenses at 632.8 nm
Profilometry
Surface form against the released aspheric profile
Dimensional inspection
Diameter, thickness and centring per drawing
Cosmetic inspection
Surface imperfections per ISO 10110-7
Records
First article report and lot documentation
Controlled parameters

Controlled Process Specifications

RELEASED CONFIGURATION
Wavefront
RMS at 632.8 nm, per drawing (typically < 0.05 λ)
Surface form
P-V per ISO 10110-5 callout
Centring
per ISO 10110-6 callout
Surface imperfections
per ISO 10110-7 callout
Release path
First article → lot release
Reports
Per lot, on request

Related Technical Notes

Frequently Asked Questions

Can I get measured data for my lot?

Yes. Wavefront and dimensional reports per lot are available on request; state it with the order.

Which wavelength is the wavefront specified at?

632.8 nm. At other wavelengths the RMS in waves scales roughly with 632.8 / λ for the same optical path error.

Ready for DFM Review or Custom Production Quote?

Send your ISO 10110 drawing, Zemax file, or optical target specification. NDA available on request.