Reading ISO 10110 callouts on lens drawings
Codes 0/ to 6/ explained with values from catalogue drawings: stress birefringence, bubbles, homogeneity, form, centring, surface imperfections and laser damage.
The ISO 10110 series
ISO 10110 governs drawings of optical elements. Material and surface tolerances are written as short coded indications: a code number, a slash and the tolerance. The material indications sit in a table on the drawing; the surface indications sit in a column for each surface.
Code reference
| Code | Property | Part | Catalogue value | Meaning |
|---|---|---|---|---|
| 0/ | Stress birefringence | 10110-2 | 0/10 | At most 10 nm of optical path difference per cm of glass |
| 1/ | Bubbles and inclusions | 10110-3 | 1/5×0.1 | Up to 5 bubbles or inclusions of grade 0.1 mm, or their equivalent area |
| 2/ | Inhomogeneity and striae | 10110-4 | 2/1;2 | Homogeneity class 1, striae class 2 |
| 3/ | Surface form tolerance | 10110-5 | 0.5 µm P-V | Largest deviation of the surface from its nominal profile |
| 4/ | Centring tolerance | 10110-6 | 4/2′ | Surface tilt up to 2 arcmin; catalogue values are measured in transmission |
| 5/ | Surface imperfections | 10110-7 | 5/2×0.1; L1×0.01; E0.1 | Two imperfections of grade 0.1 mm; one long scratch up to 0.01 mm wide; edge chips up to 0.1 mm |
| 6/ | Laser damage threshold | 10110-17 | 6/– or 1000 W/cm² | Not specified, or the rated threshold |
A grade number is the square root of the imperfection area, in millimetres: grade 0.1 is a defect area of 0.01 mm². In 2/, higher class numbers are tighter.
Aspheric surfaces
ISO 10110-12 sets how an aspheric surface is described and toleranced. The surface equation and its coefficients define the nominal profile; the form tolerance applies to the deviation from that profile, often over a stated diameter. A production drawing carries the complete description under its revision. Lens pages show the surface type of each side (asphere, sphere or plano), the clear aperture and the tolerances.
Units of form and wavefront
Our drawings give surface form in micrometres P-V and the transmitted wavefront as RMS in waves at 632.8 nm. Where a drawing gives form in fringes, one fringe is half the test wavelength, which ISO 10110-5 takes as 546.07 nm unless the drawing states another. The link between the two is explained in wavefront error and the diffraction limit.
Tolerancing a custom lens
- Tolerance what the function needs: transmitted wavefront for beam quality, centring for pointing, imperfections for scatter.
- Tighter imperfection grades cost yield; specify them over the clear aperture only.
- Centring matters most on the steep surface of a high-NA lens.
- Specify a laser damage threshold only when the power density calls for it, with wavelength and pulse format.
Frequently Asked Questions
Do you supply ISO 10110 drawings?
Yes. Custom parts are released on ISO 10110 drawings for approval, and catalogue parts have dimensioned drawings.
What does "transmission" after the centring tolerance mean?
The tilt is measured as the deviation of a beam through the lens, which is its optical effect, rather than as the mechanical runout of each surface.
Recommended Catalogue Parts
Related Technical Notes
What an RMS wavefront specification at 632.8 nm means for beam quality, how to convert it between wavelengths and how it relates to surface form.
Fresnel loss, back-reflection into the diode and angle of incidence: when to use a broadband, narrow-band or V-coat on a molded collimator.
How a molded lens moves from approved drawing to repeat production: what the first article proves, what each lot is checked against and which documents ship with it.