[protected]
ISO 9001 · ISO 14001 · IATF 16949 · ISO 13485 · ISO 10110

Quality Assurance, Optical Metrology & Compliance

Quality is engineered into every step — from low-Tg glass preform qualification and ISO 5 (Class 100) cleanroom assembly to 632.8 nm interferometry, MIL-PRF-13830B cosmetic inspection and traceable lot release.

01 · Management System Certifications

Four Core Quality & Environmental Certifications

ISO 9001
Quality Management System

End-to-end quality control across drawing review, mold tooling, isothermal glass molding, AR coating and lot release.

ISO 14001
Environmental Management System

Structured environmental stewardship covering optical fabrication chemicals, energy use and clean manufacturing.

IATF 16949
Automotive Quality Standard

Process discipline, statistical stability and traceability for automotive LiDAR, sensing and industrial OEM programs.

ISO 13485
Medical Devices Quality System

Documented quality controls supporting flow cytometry, fluorescence diagnostics and medical laser delivery optics.

ISO 5 (Class 100) Cleanroom Assembly Mounted barrel assembly and live-beam laser diode alignment are performed in a controlled ISO 5 (Class 100) cleanroom to eliminate particulate scatter and short-wavelength contamination.
CNAS Laboratory Accreditation Scope Where the in-house metrology laboratory is covered by valid CNAS accreditation, optical testing and calibration activities are performed within the approved accreditation scope.
02 · In-House Optical & Mechanical Verification

Controlled Inspection Parameters

Transmitted Wavefront Interferometry
632.8 nm phase-shifting interferometry down to < 0.04λ RMS (36+ catalog lenses meet the ≤ 0.071λ Maréchal diffraction limit)
Aspheric Surface Profilometry
Verified against released aspheric profile, typically 0.3–1.0 µm P-V per ISO 10110-5
Cosmetic Surface Inspection
Rigorous batch cosmetic screening to MIL-PRF-13830B 40-20 and ISO 10110-7 callouts
Centring & Dimensional Metrology
Transmission optical centring (typically 2 arcmin) and precision ground OD (+0 / −0.02 mm typical)
Coating Witness Verification
Measured reflectance curves per coating run; adhesion, humidity and abrasion durability per MIL-PRF-13830B
100% Module Pointing Test
Every laser diode module is measured on a far-field camera (≤ 1 mrad to the h8 body cylinder datum)
Transmitted wavefront interferometry at 632.8 nm
Interferometric test of a finished molded asphere in transmission at 632.8 nm.
ISO 10110 & MIL-PRF-13830B

Full support for ISO 10110 (0/ to 6/ material & surface codes), MIL-PRF-13830B 40-20 cosmetic quality, Zemax/STEP engineering models and measured AR reflectance curves.

03 · Production Release & Traceability

From First Article Inspection (FAI) to Repeat Lot Release

Read FAI & lot release guide →
STEP 01

Drawing & Spec Freeze

Confirm ISO 10110 drawing revision, RMS wavefront limit, coating band and acceptance plan.

STEP 02

First Article Inspection (FAI)

Run on production mold tool and glass; every drawing characteristic measured and approved to freeze the baseline.

STEP 03

AQL Lot Verification

Production lots sampled per agreed ISO 2859-1 AQL plan with full traceability to mold cavity, glass melt and coating run.

STEP 04

Controlled Lot Release

Certificate of Conformance (CoC) ships with every lot; measured wavefront and dimensional reports supplied on request.

04 · Certificates, Declarations & Lot Records

Request Quality & Compliance Documentation

Add any certificate, environmental declaration (RoHS, REACH SVHC, TSCA) or lot inspection record to your request list for fast delivery.

PDF On request

ISO 9001 certificate

Quality management system certificate.

PDF On request

ISO 14001 certificate

Environmental management system certificate.

PDF On request

IATF 16949 certificate

Automotive quality management system certificate.

PDF On request

ISO 13485 certificate

Medical devices quality management system certificate.

PDF On request

RoHS declaration

Declaration of conformity with EU RoHS (2011/65/EU and amendments), per part number.

PDF On request

REACH SVHC statement

Statement on substances of very high concern under EU REACH, per part number.

PDF On request

TSCA statement

Statement under the US Toxic Substances Control Act, per part number.

PDF On request

Certificate of conformance

Issued with each lot against the released drawing.

PDF On request

Lot inspection report

Measured wavefront and dimensional data for a delivered lot.

PDF On request

Glass data

Refractive index and material data of the molding glass of a lens.