[protected]
Industrial Sensing

Machine Vision & Laser Triangulation

Dot and line projectors for triangulation sensors, 3D profilers and structured-light vision.

Machine Vision & Laser Triangulation
Design wavelengths
405, 408, 445, 633, 635, 639, 650 nm
Focal length
3.2–15.26 mm, tolerance ±1 %
Numerical aperture
0.18–0.63
Diameter
Ø3–10.5 mm
Window correction
0.25 mm N-BK7; 0.3 mm N-BK7; 1.2 mm PC; no window
Transmitted wavefront (RMS)
< 0.04 to < 0.15 λ at 632.8 nm, as molded (9 of 12 at ≤ 0.05 λ)
Centring (transmission)
2 arcmin on 12 of 12 lenses
Surface form
0.5–1 µm P-V
Glass
CDGM D-LAK6, CDGM D-ZK3, CDGM D-ZLAF52LA, D-ZK3, OHARA L-BAL42
Coatings
BBAR-NIR-I, BBAR-VIS, NBAR-GRN, NBAR-RED, NBAR-VIO, V-coat at the design line
Module pointing
≤ 1 mrad to the body axis, measured per module

Optical Requirements & Rationale

Spot size and depth

The finest height step a triangulation sensor can resolve is set by how precisely the camera locates the spot, which depends on the spot size and on speckle. A small waist resolves fine detail but grows quickly with distance; sensors with a large measuring range use a larger waist. The lens focal length and the diode's emitter set both.

Wavelength

Blue 405 to 450 nm lasers give smaller spots and penetrate less into translucent and organic materials, and they reflect better from hot, glowing metal; red 635 to 660 nm remains the standard for general use. Changing wavelength changes the speckle and the material response, not the geometry.

Selection Strategy

<p>The diode is focused by an asphere so that its waist sits in the middle of the measuring range; for a line profiler a cylindrical or Powell lens then spreads it into a line. The camera views the spot at a triangulation angle of typically 20° to 45°.</p><p>Because the sensor is calibrated against its own geometry, the laser must not move relative to the housing; a pre-aligned module with a defined body datum keeps the calibration valid through service and replacement.</p>

Machine Vision & Laser Triangulation diagram

Key Advantages

  • Blue and red designs. 405 to 445 nm and 633 to 660 nm lenses and modules.
  • Stable spot. Glass lens and welded or epoxy-fixed alignment hold the spot position.
  • Defined datum. Module body cylinder (h8) as the mounting reference.
  • Focused to your range. Module focus can be set to a working distance on request.

Frequently Asked Questions

Can the module be focused instead of collimated?

Yes. Tell us the working distance and we set the focus there during alignment.

Which is better, blue or red?

Blue gives smaller spots and better results on hot metal and organic or translucent surfaces; red is cheaper and standard for general metrology.

Do you supply line optics?

We supply the collimated or focused source; the line optic is part of your head or quoted as an engineered module.